Skip to main content

Customised solution for Railway black box

The HFC-3W/O DC/DC converter was selected for its superior isolation and integrated cooling plate. This converter serves as a prime example of how DC/DC converters can be tailored to meet bespoke application requirements.

To align with updated standards and evolving requirements, Autronic collaborated closely with the client to ensure all specifications were met.

Application: The converter is designed for black boxes that record information under extreme operating temperatures, particularly for use in overseas applications.

Key Features:

  • Wide Input Range: The converter supports an ultrawide input range from 14.4 to 154 VDC, suitable for all standard nominal input voltages as per EN 50155.
  • Enhanced Protection: An RIA 12 filter allows the converter to endure high voltages (waveform A to G) without damage or operational interruption. Additionally, it offers increased surge protection according to IEEE 1482.1, handling up to 80 J of source energy.
  • Output & Stability: It delivers a total output power of 43W, distributed over three outputs (5.1, 12, and -12 VDC). In the event of input voltage failure, the outputs continue functioning for up to 20 ms, allowing for safe system shutdown and data preservation.
  • Robust Performance: The converter is capable of operating in extreme conditions, with temperatures as low as -55°C, meeting EN 50155 Class TX standards. It can also sustain continuous function in environments up to 70°C and briefly (up to 10 minutes) at 85°C without derating. This performance is achieved through a custom design focused on minimizing thermal load, ensuring a maximum temperature delta of 15°C between hot spots and ambient conditions.
  • Traceability & Customization: Autronic provides full traceability of components, and customization options include customer-specific identification. This ensures clear allocation of each power supply and supports the traceability of components during production.
  • Fire Safety & Reliability: Compliance with fire protection standards (NF F and EN 45545-2) is assured. The converter’s reliability is rated over 1.1 million hours under IEC 62380 standards at 60°C.

Summary:

  • Input Voltage: 14.4 to 154 VDC
  • Output Voltage: 5.1, 12, and -12 VDC
  • Power Output: 43W
  • Temperature Range: Class TX (EN 50155)
  • Hold-Up Time: 20 ms

Main Features:

  • RIA 12 protection (waveforms A to G)
  • Reverse polarity protection up to 160 V
  • Inrush current limitation
  • Overcurrent, overtemperature, and overvoltage protection
  • Digital serial number identification

Standards & Compliance:

  • IEEE 1482.1
  • IEEE 1478
  • EN 50155
  • EN 50121-3-2
  • EN 61373
  • EN 45545-2
Contact us